4.1Cable design and construction
Cables in accordance with,or conforming to,IEC 61196 sectional or detail specificationsshould be specified wherever possible. Where cable designs deviating from lEC 61196sectional or detail specifications are required,these cables shall comply with therequirements of the relevant sectional or detail specification of the manufacturer.
According to local regulation,raw material of the cable as well as those of additionalprotection shall be chosen to comply with regional or national Directives and Regulations suchas RoHS and REACH in Europe.
4.2Connector design and construction
Connector types conforming to the relevant part of lEC 61169 shall be specified whereverpossible, but where a special connector design is required, the interface shall conform to therelevant part of lEC 61169, where available,and the connector construction shall comply withthe requirements of the relevant detail specification.
According to local regulation,raw material of the connector as well as those of additionalprotection shall be chosen to comply with RoHS and other environmental regulation such asREACH in Europe.
4.3outline and interface dimensions
Outline dimensions shall be in accordance with the relevant detail specification of the cableassembly.
Interface dimensions shall be in accordance with the relevant detail specification.
5 Workmanship, marking and packaging
5.1Workmanship
There shall be no observable defects in the cable assembly. lt shall be clean and in goodcondition.
5.2Marking
Marking shall be legible and in accordance with the relevant detail specification. lt shallidentify the manufacturer of the cable assembly.
5.3End caps
Unless otherwise specified in the relevant detail specification, disposable end caps of suitablematerial for transport and storage shall be fitted to the connectors to protect at least eachinterface from damage and dirt.
5.4Packaging and labelling
Packaging and labelling shall be in accordance with the relevant detail specification,unlessotherwise specified.
6 Quality management
A guide for quality management including capability approval as well as qualification approvalis given in Annex D.EN IEC 60966-1 pdf download.