IEC 60384-11-2019 pdf free.Fixed capacitors for use in electronic equipment-Part 11: Sectional specification -Fixed polyethylene-terephthalate film dielectric metal foil DC capacitors.
This part of lEC 60384 is applicable to fixed direct current capacitors, for rated voltages notexceeding 6 300 V, using as dielectric a polyethylene-terephthalate film and electrodes of thinmetal foils. For capacitors with rated voltages exceeding 1 000 V, additional tests andrequirements may be specified in the detail specification.
The capacitors covered by this document are intended for use in electronic equipment.
Capacitors for electromagnetic interference suppression are not included, but are coveredby IEC 60384-14.
The object of this document is to prescribe preferred ratings and characteristics and to selectfrom lEC 60384-1:2016 the appropriate quality assessment procedures, tests and measuringmethods and to give general performance requirements for this type of capacitor. Testseverities and requirements prescribed in detail specifications referring to this sectionalspecification are of an equal or higher performance level.Lower performance levels are notpermitted.
Normative references
The following documents are referred to in the text in such a way that some or all of theircontent constitutes requirements of this document.For dated references, only the edition citedapplies.For undated references, the latest edition of the referenced document (including anyamendments) applies.
IEC 60062,Marking codes for resistors and capacitors
IEC 60063,Preferred number series for resistors and capacitors
IEC 60068-1:2013,Environmental testing – Part 1: General and guidance
Visual examination shall be carried out with suitable equipment with approximately 10×magnification and lighting appropriate to the specimen under test and the quality levelrequired.
The operator should have available facilities for incident or transmitted illumination as well asan appropriate measuring facility.
The capacitors shall be examined to verify that the materials,design,construction andphysical dimensions are appropriate.
See Table 10. The workmanship shall be in accordance with the applicable requirements given in the detailspecification.
The voltages given in Table 2 shall be applied between the measuring points (fromIEC 60384-1:2016,Table 3) for a period of 1 min for qualification approval testing andbetween measuring point 1a) for a period of 1 s for the lot-by-lot quality conformance testing.IEC 60384-11 pdf download.