IEC 62893-3-2017 pdf free.Charging cables for electric vehicles of rated voltages up to and including 0,6/1 kV – Part 3: Cables for AC charging according to modes 1, 2 and 3 of IEC 61851-1 of rated voltages up to and including 450/750 V.
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (lncludin9 any amendments) applies.
IEC 60245-2:1994, Rubber insulated cables — Rated voltages up to and including 450/750 V — Part 2: Test methods
lEG 60332-1 -2, Tests on electric and optical fibre cables under fire conditions — Part 1-2: Test for vertical flame propagation for a single insulated wire or cable — Procedure for 1 kW premixed flame
IEC 60811-401:2012, Electric and optical fibre cables — Test methods for non-metallic materials — Part 401: Miscellaneous tests — Thermal ageing methods — Ageing in an air oven
IEC 60811-505, Electric and optical fibre cables — Test methods for non-metallic materials — Part 505: Mechanical tests — Elongation at low temperature for insulations and sheaths
lEG 61851-1, Electric vehicle conductive charging system — Part 1: General requirements lEG 62440:2008, Electric cables with a rated voltage not exceeding 450/750 V — Guide to use
IEC 62821-1:2015, Electric cables — Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V — Part 1: General requirements
IEC 62893-1 :2017, Charging cables for electric vehicles of rated voltages up to and including 0,6/1 k V — Part 1: General requirements
3 Terms and definitions
For the purposes of this document, the terms and definitions given in lEG 62893-1 apply.
ISO and lEG maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
4 General purpose cables
4.1 Ordinary duty flexible cables
4.1.1 Code designation The code designation is 62893 IEC 121 for halogen free cables with sheath compound EVM-1 and 62893 IEC 122 for halogen free cables with sheath compound EVM-2.
4.1.2 Rated voltage 300/500 V
4.1.3 Construction
4.1.3.1 Sizes of cable The sizes of cable shall be:1,5 mm2 and 2,5 mm2 — 3 power cores
4.1.3.2 Insulation The insulation of the power cores shall be compound of type EVI-2 to IEC 62893-1.
4.1.3.3 Assembly The cores shall be twisted together. A tape may be applied around the core assembly before application of the sheath.
4.1.3.4 Sheath The sheath shall be compound of type EVM-1 to lEG 62893-1 for cable type 62893 IEC 121 and EVM-2 to IEC 62893-1 for cable type 62893 lEG 122.IEC 62893-3 pdf download.